Aħna grupp kwalifikat u ta 'effiċjenza biex noffru appoġġ eċċellenti għall-klijent tagħna.Aħna normalment isegwu l-Prinċipju ta 'Orjentat lejn il-klijent, iffukat fuq id-dettalji għall-Provvista OEM / ODM 4 Core XLPE Insulated PVC Sheathed Unarmoured Power Cable / Flexible Flame Retardant Power Cable, Bħalissa, qed infittxu 'l quddiem għal kooperazzjoni saħansitra akbar ma' xerrejja barranin determinati minn reċiproku benefiċċji.Jekk jogħġbok tħossok assolutament liberu li tikkuntattjana għal aktar dettalji.
Aħna grupp kwalifikat u ta 'effiċjenza biex noffru appoġġ eċċellenti għall-klijent tagħna.Aħna normalment isegwu l-Prinċipju ta 'orjentat lejn il-klijent, iffukat fuq id-dettaljiĊina Copper Cable u PVC Insulated Ram, Billi żżomm mal-prinċipju ta '"orjentat lejn il-bniedem, rebbieħa bil-kwalità", il-kumpanija tagħna tilqa' sinċerament negozjanti mid-dar u barra biex iżuruna, jitkellmu negozju magħna u flimkien joħolqu futur brillanti.
Applikazzjoni
Trunking tal-kejbils fuq ġewwa, barra għal power stations, industrija u switchgear kif ukoll għal netwerks ta 'provvista urbani, jekk ħsara mekkanika hija improbabbli
Kostruzzjoni
Karatteristiċi
Vultaġġ nominali: 0.6/1kV
1. matul it-tħaddim normali tal-kejbil, it-temperatura massima tal-konduttur għandha tkun 70℃ għal insulazzjoni tal-PVC u 90℃ għal insulazzjoni XLPE.
2.Temperatura massima tal-konduttur waqt ċirkwit qasir (tul massimu li ma jaqbiżx il-5 sekondi): Insulazzjoni tal-PVC - 160℃ għal sezzjoni trasversali tal-konduttur ≤300mm2, 140℃ għal sezzjoni trasversali tal-konduttur > 300mm2;Insulazzjoni tal-PVC crosslinked f'250℃.
3.Meta tpoġġi l-kejbils, it-temperatura ambjentali m'għandhiex tkun inqas minn 0 ℃, u r-raġġ minimu permissibbli tal-liwi huwa kif ġej:
Kejbil tal-qalba waħda: 20D mhux armored, 15D armored
Cable multi-core: 15D għal mhux armati, 12D għal armati
Fejn: D- dijametru ta' barra attwali tal-kejbil.
4.Forza tal-ksur tal-kejbil:
Kejbil tal-qalba tal-aluminju: 40×S (N)
Kejbil tal-qalba tar-ram: 70×S (N)
Nota: S hija l-erja tas-sezzjoni trasversali totali tal-konduttur
Standards
IEC 60502-1, GB/T 12706.1
Parametri
Kejbil Uniku tal-Qawwa tal-Qawwa | ||||||||
Nom.Sezzjoni trasversali tal-konduttur | Ħxuna ta 'insulazzjoni | Ħxuna tal-għant | Appross.OD | Piż approssimattiv | Max.Reżistenza DC tal-konduttur (20°C) | Test Vultaġġ AC | Klassifikazzjoni kurrenti | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | Fl-arja (A) | Fil-ħamrija (A) |
1×1.5 | 0.7 | 1.4 | 6 | 53 | 12.1 | 3.5 | 22 | 33 |
1×2.5 | 0.7 | 1.4 | 6 | 68 | 7.41 | 3.5 | 31 | 43 |
1×4 | 0.7 | 1.4 | 7 | 87 | 4.61 | 3.5 | 41 | 56 |
1×6 | 0.7 | 1.4 | 7 | 110 | 3.08 | 3.5 | 52 | 70 |
1×10 | 0.7 | 1.4 | 8 | 155 | 1.83 | 3.5 | 71 | 94 |
1×16 | 0.7 | 1.4 | 9 | 220 | 1.15 | 3.5 | 92 | 120 |
1×25 | 0.9 | 1.4 | 10 | 345 | 0.727 | 3.5 | 120 | 155 |
1×35 | 0.9 | 1.4 | 12 | 424 | 0.524 | 3.5 | 150 | 185 |
1×50 | 1 | 1.4 | 13 | 555 | 0.387 | 3.5 | 180 | 220 |
1×70 | 1.1 | 1.4 | 14 | 770 | 0.268 | 3.5 | 230 | 270 |
1×95 | 1.1 | 1.5 | 16 | 1040 | 0.193 | 3.5 | 285 | 320 |
1×120 | 1.2 | 1.5 | 18 | 1290 | 0.153 | 3.5 | 335 | 365 |
1×150 | 1.4 | 1.6 | 20 | 1590 | 0.124 | 3.5 | 385 | 410 |
1×185 | 1.6 | 1.6 | 22 | 1944 | 0.0991 | 3.5 | 450 | 465 |
1×240 | 1.7 | 1.7 | 25 | 2510 | 0.0754 | 3.5 | 535 | 540 |
1×300 | 1.8 | 1.8 | 27 | 3042 | 0.0601 | 3.5 | 620 | 610 |
1×400 | 2 | 1.9 | 31 | 3869 | 0.047 | 3.5 | 720 | 695 |
1×500 | 2.2 | 2.1 | 35 | 4910 | 0.0366 | 3.5 | 835 | 780 |
1×630 | 2.4 | 2.2 | 40 | 6220 | 0.0283 | 3.5 | 960 | 880 |
1×800 | 2.6 | 2.4 | 45 | 7870 | 0.0221 | 3.5 | 1110 | 970 |
1×1000 | 2.8 | 2.6 | 51 | 9804 | 0.0176 | 3.5 | 1230 | 1060 |
2 Core Power Cable | ||||||||
Nom.Sezzjoni trasversali tal-konduttur | Ħxuna ta 'insulazzjoni | Ħxuna tal-għant | Appross.OD | Piż approssimattiv | Max.Reżistenza DC tal-konduttur (20°C) | Test Vultaġġ AC | Klassifikazzjoni kurrenti | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | Fl-arja (A) | Fil-ħamrija (A) |
2×2.5 | 0.7 | 1.8 | 11.8 | 151 | 7.41 | 3.5 | 26 | 35 |
2×4 | 0.7 | 1.8 | 12.7 | 198 | 4.61 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1.8 | 13.7 | 250 | 3.08 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1.8 | 15 | 374 | 1.83 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1.8 | 17 | 518 | 1.15 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1.8 | 20 | 772 | 0.727 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1.8 | 22 | 1006 | 0.524 | 3.5 | 125 | 155 |
2×50 | 1 | 1.8 | 20 | 1365 | 0.387 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1.8 | 21 | 1872 | 0.268 | 3.5 | 200 | 225 |
2×95 | 1.1 | 1.8 | 24 | 2475 | 0.193 | 3.5 | 245 | 270 |
2×120 | 1.2 | 1.8 | 27 | 3089 | 0.153 | 3.5 | 285 | 310 |
2×150 | 1.4 | 1.9 | 30 | 3834 | 0.124 | 3.5 | 325 | 345 |
3 Core Power Cable | ||||||||
Nom.Sezzjoni trasversali tal-konduttur | Ħxuna ta 'insulazzjoni | Ħxuna tal-għant | Appross.OD | Piż approssimattiv | Max.Reżistenza DC tal-konduttur (20°C) | Test Vultaġġ AC | Klassifikazzjoni kurrenti | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | Fl-arja (A) | Fil-ħamrija (A) |
3×1.5 | 0.7 | 1.5 | 10 | 145 | 12.1 | 3.5 | 20 | 27 |
3×2.5 | 0.7 | 1.5 | 11 | 185 | 7.41 | 3.5 | 26 | 35 |
3×4 | 0.7 | 1.5 | 12 | 250 | 4.61 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1.5 | 13 | 320 | 3.08 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1.8 | 16 | 450 | 1.83 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1.8 | 18 | 640 | 1.15 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1.8 | 21 | 940 | 0.727 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1.8 | 23 | 1260 | 0.524 | 3.5 | 125 | 155 |
3×50 | 1 | 1.8 | 23 | 1670 | 0.387 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1.8 | 26 | 2280 | 0.268 | 3.5 | 200 | 225 |
3×95 | 1.1 | 1.9 | 30 | 3020 | 0.193 | 3.5 | 245 | 270 |
3×120 | 1.2 | 2 | 32 | 3790 | 0.153 | 3.5 | 285 | 310 |
3×150 | 1.4 | 2.2 | 37 | 4750 | 0.124 | 3.5 | 325 | 345 |
3×185 | 1.6 | 2.3 | 41 | 5654 | 0.0991 | 3.5 | 375 | 390 |
3×240 | 1.7 | 2.4 | 46 | 7243 | 0.0754 | 3.5 | 440 | 450 |
3×300 | 1.8 | 2.6 | 51 | 9465 | 0.0601 | 3.5 | 505 | 515 |
3×400 | 2 | 3 | 64 | 12066 | 0.047 | 3.5 | 570 | 575 |
4 Core Power Cable | ||||||||
Nom.Sezzjoni trasversali tal-konduttur | Ħxuna ta 'insulazzjoni | Ħxuna tal-għant | Appross.OD | Piż approssimattiv | Max.Reżistenza DC tal-konduttur (20°C) | Test Vultaġġ AC | Klassifikazzjoni kurrenti | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | Fl-arja (A) | Fil-ħamrija (A) |
4×4 | 0.7 | 1.8 | 13 | 253 | 4.61 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1.8 | 14 | 337 | 3.08 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1.8 | 17 | 501 | 1.83 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1.8 | 20 | 778 | 1.15 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1.8 | 23 | 1160 | 0.727 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1.8 | 25 | 1554 | 0.524 | 3.5 | 125 | 155 |
4×50 | 1 | 1.8 | 23 | 2148 | 0.387 | 3.5 | 160 | 185 |
4×70 | 1.1 | 1.8 | 27 | 2928 | 0.268 | 3.5 | 200 | 225 |
4×95 | 1.1 | 1.9 | 31 | 3854 | 0.193 | 3.5 | 245 | 270 |
4×120 | 1.2 | 2 | 33 | 4925 | 0.153 | 3.5 | 285 | 310 |
4×150 | 1.4 | 2.2 | 38 | 6238 | 0.124 | 3.5 | 325 | 345 |
4×185 | 1.6 | 2.3 | 42 | 7562 | 0.0991 | 3.5 | 375 | 390 |
4×240 | 1.7 | 2.5 | 47 | 9836 | 0.0754 | 3.5 | 440 | 450 |
4×300 | 1.8 | 2.6 | 52 | 12550 | 0.0601 | 3.5 | 505 | 515 |
4×400 | 2 | 3.1 | 66 | 15929 | 0.047 | 3.5 | 570 | 575 |
5 Core Power Cable | ||||||||
Nom.Sezzjoni trasversali tal-konduttur | Ħxuna ta 'insulazzjoni | Ħxuna tal-għant | Appross.OD | Piż approssimattiv | Max.Reżistenza DC tal-konduttur (20°C) | Test Vultaġġ AC | Klassifikazzjoni kurrenti | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | Fl-arja (A) | Fil-ħamrija (A) |
5×4 | 0.7 | 1.8 | 14.5 | 349 | 4.61 | 3.5 | 34 | 45 |
5×6 | 0.7 | 1.8 | 15.8 | 460 | 3.08 | 3.5 | 43 | 57 |
5×10 | 0.7 | 1.8 | 19 | 699 | 1.83 | 3.5 | 60 | 77 |
5×16 | 0.7 | 1.8 | 22 | 1013 | 1.15 | 3.5 | 83 | 105 |
5×25 | 0.9 | 1.8 | 25 | 1566 | 0.727 | 3.5 | 105 | 125 |
5×35 | 0.9 | 1.9 | 28 | 2083 | 0.524 | 3.5 | 125 | 155 |
5×50 | 1 | 2 | 31 | 2921 | 0.387 | 3.5 | 160 | 185 |
5×70 | 1.1 | 2.1 | 36 | 3974 | 0.268 | 3.5 | 200 | 225 |
5×95 | 1.1 | 2.2 | 39 | 5297 | 0.193 | 3.5 | 245 | 270 |
5×120 | 1.2 | 2.4 | 44 | 6638 | 0.153 | 3.5 | 285 | 310 |
5×150 | 1.4 | 2.5 | 49 | 8290 | 0.124 | 3.5 | 325 | 345 |
5×185 | 1.6 | 2.7 | 55 | 10215 | 0.0991 | 3.5 | 375 | 390 |
5×240 | 1.7 | 3 | 64 | 13130 | 0.0754 | 3.5 | 440 | 450 |
5×300 | 1.8 | 3.2 | 70 | 16670 | 0.0601 | 3.5 | 505 | 515 |
3 + 1 Core Power Cable | ||||||||
Nom.Sezzjoni trasversali tal-konduttur | Ħxuna ta 'insulazzjoni | Ħxuna tal-għant | Appross.OD | Piż approssimattiv | Max.Reżistenza DC tal-konduttur (20°C) | Test Vultaġġ AC | Klassifikazzjoni kurrenti | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | Fl-arja (A) | Fil-ħamrija (A) |
3×4+1×2.5 | 0.7 | 1.8 | 13 | 236 | 4.61 | 3.5 | 34 | 45 |
3×6+1×4 | 0.7 | 1.8 | 14 | 316 | 3.08 | 3.5 | 43 | 57 |
3×10+1×6 | 0.7 | 1.8 | 17 | 461 | 1.83 | 3.5 | 60 | 77 |
3×16+1×10 | 0.7 | 1.8 | 19 | 679 | 1.15 | 3.5 | 83 | 105 |
3×25+1×16 | 0.9 | 1.8 | 22 | 1065 | 0.727 | 3.5 | 105 | 125 |
3×35+1×16 | 0.9 | 1.8 | 24 | 1360 | 0.524 | 3.5 | 125 | 155 |
3×50+1×25 | 1 | 1.8 | 25 | 1901 | 0.387 | 3.5 | 160 | 185 |
3×70+1×35 | 1.1 | 1.9 | 28 | 2585 | 0.268 | 3.5 | 200 | 225 |
3×95+1×50 | 1.1 | 2 | 32 | 3518 | 0.193 | 3.5 | 245 | 270 |
3×120+1×70 | 1.2 | 2.1 | 35 | 4443 | 0.153 | 3.5 | 285 | 310 |
3×150+1×70 | 1.4 | 2.2 | 40 | 5326 | 0.124 | 3.5 | 325 | 345 |
3×185+1×95 | 1.6 | 2.4 | 43 | 8501 | 0.0991 | 3.5 | 375 | 390 |
3×240+1×120 | 1.7 | 2.5 | 48 | 11155 | 0.0754 | 3.5 | 440 | 450 |
3×300+1×150 | 1.8 | 2.7 | 54 | 14470 | 0.0601 | 3.5 | 505 | 515 |
3×400+1×240 | 2 | 3.1 | 66 | 309 | 0.047 | 3.5 | 570 | 575 |
3 + 2 Kejbil tal-Qawwa tal-Qawwa | ||||||||
Nom.Sezzjoni trasversali tal-konduttur | Ħxuna ta 'insulazzjoni | Ħxuna tal-għant | Appross.OD | Piż approssimattiv | Max.Reżistenza DC tal-konduttur (20°C) | Test Vultaġġ AC | Klassifikazzjoni kurrenti | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | Fl-arja (A) | Fil-ħamrija (A) |
3×4+2×2.5 | 0.7 | 1.8 | 13.9 | 413 | 4.61 | 3.5 | 34 | 45 |
3×6+2×4 | 0.7 | 1.8 | 15.3 | 6682 | 3.08 | 3.5 | 43 | 57 |
3×10+2×6 | 0.7 | 1.8 | 18 | 603 | 1.83 | 3.5 | 60 | 77 |
3×16+2×10 | 0.7 | 1.8 | 21 | 888 | 1.15 | 3.5 | 83 | 105 |
3×25+2×16 | 0.9 | 1.8 | 24 | 1342 | 0.727 | 3.5 | 105 | 125 |
3×35+2×16 | 0.9 | 1.8 | 26 | 1647 | 0.524 | 3.5 | 125 | 155 |
3×50+2×35 | 1 | 1.9 | 29 | 2386 | 0.387 | 3.5 | 160 | 185 |
3×70+2×35 | 1.1 | 2 | 32 | 3201 | 0.268 | 3.5 | 200 | 225 |
3×95+2×50 | 1.1 | 2.1 | 36 | 4269 | 0.193 | 3.5 | 245 | 270 |
3×120+2×70 | 1.2 | 2.3 | 41 | 5437 | 0.153 | 3.5 | 285 | 310 |
3×150+2×70 | 1.4 | 2.4 | 44 | 6519 | 0.124 | 3.5 | 325 | 345 |
3×185+2×95 | 1.6 | 2.5 | 49 | 8101 | 0.0991 | 3.5 | 375 | 390 |
3×240+2×120 | 1.7 | 2.7 | 54 | 10340 | 0.0754 | 3.5 | 440 | 450 |
3×300+2×150 | 1.8 | 2.8 | 56 | 12810 | 0.0601 | 3.5 | 505 | 515 |
4 + 1 Core Power Cable | ||||||||
Nom.Sezzjoni trasversali tal-konduttur | Ħxuna ta 'insulazzjoni | Ħxuna tal-għant | Appross.OD | Piż approssimattiv | Max.Reżistenza DC tal-konduttur (20°C) | Test Vultaġġ AC | Klassifikazzjoni kurrenti | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | Fl-arja (A) | Fil-ħamrija (A) |
4×4+1×2.5 | 0.7 | 1.8 | 14.5 | 331 | 4.61 | 3.5 | 34 | 45 |
4×6+1×4 | 0.7 | 1.8 | 15.9 | 435 | 3.08 | 3.5 | 43 | 57 |
4×10+1×6 | 0.7 | 1.8 | 18 | 649 | 1.83 | 3.5 | 60 | 77 |
4×16+1×10 | 0.7 | 1.8 | 21 | 965 | 1.15 | 3.5 | 83 | 105 |
4×25+1×16 | 0.9 | 1.8 | 25 | 1456 | 0.727 | 3.5 | 105 | 125 |
4×35+1×16 | 0.9 | 1.8 | 27 | 1863 | 0.524 | 3.5 | 125 | 155 |
4×50+1×25 | 1 | 1.9 | 29 | 2633 | 0.387 | 3.5 | 160 | 185 |
4×70+1×35 | 1.1 | 2 | 32 | 3565 | 0.268 | 3.5 | 200 | 225 |
4×95+1×50 | 1.1 | 2.1 | 36 | 4735 | 0.193 | 3.5 | 245 | 270 |
4×120+1×70 | 1.2 | 2.3 | 41 | 5977 | 0.153 | 3.5 | 285 | 310 |
4×150+1×70 | 1.4 | 2.4 | 44 | 7276 | 0.124 | 3.5 | 325 | 345 |
4×185+1×95 | 1.6 | 2.5 | 49 | 9055 | 0.0991 | 3.5 | 375 | 390 |
4×240+1×120 | 1.7 | 2.7 | 54 | 11567 | 0.0754 | 3.5 | 440 | 450 |
4×300+1×150 | 1.8 | 3.1 | 66 | 14321 | 0.0601 | 3.5 | 505 | 515 |
Aħna grupp kwalifikat u ta 'effiċjenza biex noffru appoġġ eċċellenti għall-klijent tagħna.Aħna normalment isegwu l-Prinċipju ta 'Orjentat lejn il-klijent, iffukat fuq id-dettalji għall-Provvista OEM / ODM 4 Core XLPE Insulated PVC Sheathed Unarmoured Power Cable / Flexible Flame Retardant Power Cable, Bħalissa, qed infittxu 'l quddiem għal kooperazzjoni saħansitra akbar ma' xerrejja barranin determinati minn reċiproku benefiċċji.Jekk jogħġbok tħossok assolutament liberu li tikkuntattjana għal aktar dettalji.
Provvista OEM/ODMĊina Copper Cable u PVC Insulated Ram, Billi żżomm mal-prinċipju ta '"orjentat lejn il-bniedem, rebbieħa bil-kwalità", il-kumpanija tagħna tilqa' sinċerament negozjanti mid-dar u barra biex iżuruna, jitkellmu negozju magħna u flimkien joħolqu futur brillanti.